2Potential Password Security Weakness in SIMATIC Controllers,, website last accessed July 5, 2011.įor any questions related to this report, please contact the CISA at:įor industrial control systems cybersecurity information: ĬISA continuously strives to improve its products and services.1NSS Labs,, website last accessed June 10, 2011.ICS-CERT published a follow-up advisory titled ICSA-11-223-01 - Siemens SIMATIC PLCs Reported Issues Summary on the ICS-CERT Web page on August 21, 2011. ICS-CERT will release information concerning additional mitigations as they become available. Siemens has published a document regarding the vulnerability affecting the SIMATIC S7-200, S7-300, S7-400, and S7-1200 products. Restrict remote access to enterprise and control system networks and diligently monitor any remote connections allowed employ Virtual Private Network for any remote system connections.Siemens recommends that concerned customers block all traffic to the PROFIBUS, MPI, and PROFINET protocol-based devices from outside the Manufacturing Zone by restricting or blocking Ethernet access to 102/TCP and 102/UDP, using appropriate security technology.

SIEMENS SIMATIC S7 400 SYSTEM HOW TO

  • Defense-in-depth strategies for both enterprise and control system networks see the ICS-CERT Recommended Practice document, Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies and Siemens’ Industrial Security website for more information on how to apply these measures.
  • Changing this password frequently and using unique passwords, when possible, will reduce exposure to this vulnerability.
  • ICS-CERT and Siemens recommend that asset owners/operators apply a properly configured strong password to each PLC.
  • The following mitigations can be implemented to reduce the risk of impact by the reported vulnerabilities: ICS-CERT continues to work with Siemens to develop specific mitigations for the reported vulnerabilities.

    siemens simatic s7-400 system siemens simatic s7-400 system

    The ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their environment, architecture, and operational product implementation.

    SIEMENS SIMATIC S7 400 SYSTEM FULL

    The full impact to individual organizations is dependent on multiple factors unique to each organization. IMPACTĪn attacker with access to the PLC or the automation network could intercept the PLC password and make unauthorized changes to the PLC operation. ICS-CERT will publish additional information as it becomes available.

    siemens simatic s7-400 system

    Like ISO-TSAP, many protocols used in industrial control systems were intentionally designed to be open and without security features. According to ICS-CERT analysis, the ISO-TSAP protocol is functioning to specifications however, authentication is not performed nor are payloads encrypted or obfuscated. Siemens PLCs configured with password protection are still susceptible to a replay attack.Ĭommands between the affected PLCs and other devices are transmitted using the International Organization for Standardization Transport Service Access Point (ISO-TSAP) protocol. The replay attack vulnerabilities affecting the S7-1200 also are verified to affect the SIMATIC S7-200, S7-300, and S7-400 PLCs. Reported multiple vulnerabilities to ICS-CERT that affect the Siemens Simatic S7-1200 micro PLC as reported in ICS-ALERT-11-161-01. In May of 2011, security researcher Dillon Beresford of NSS Labs 1 ICS-CERT is continuing to coordinate with Siemens concerning vulnerabilities affecting Siemens SIMATIC Programmable Logic Controllers (PLCs).









    Siemens simatic s7-400 system